deep inspiration breath-hold with active breathing control (abc) Search Results


86
Elekta fff dibh treatments
Fff Dibh Treatments, supplied by Elekta, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/deep+inspiration+breath-hold+with+active+breathing+control+%28abc%29/pmc12781846-185-24-28?v=Elekta
Average 86 stars, based on 1 article reviews
fff dibh treatments - by Bioz Stars, 2026-08
86/100 stars
  Buy from Supplier

90
Helmholtz Zentrum fur Infektionsforschung GmbH deep inspiration breath hold (dibh) radiation therapy
Deep Inspiration Breath Hold (Dibh) Radiation Therapy, supplied by Helmholtz Zentrum fur Infektionsforschung GmbH, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/deep+inspiration+breath-hold+with+active+breathing+control+%28abc%29/10__1016_slash_j__ijrobp__2016__06__703-44-39-12?v=Helmholtz+Zentrum+fur+Infektionsforschung+GmbH
Average 90 stars, based on 1 article reviews
deep inspiration breath hold (dibh) radiation therapy - by Bioz Stars, 2026-08
90/100 stars
  Buy from Supplier

90
Vision RT Ltd optical surface monitoring system (osms)
Optical Surface Monitoring System (Osms), supplied by Vision RT Ltd, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/deep+inspiration+breath-hold+with+active+breathing+control+%28abc%29/pm37312511-32-33-39?v=Vision+RT+Ltd
Average 90 stars, based on 1 article reviews
optical surface monitoring system (osms) - by Bioz Stars, 2026-08
90/100 stars
  Buy from Supplier

90
CIVCO Medical Instruments Co Inc sinmed posiboard-2
Sinmed Posiboard 2, supplied by CIVCO Medical Instruments Co Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/deep+inspiration+breath-hold+with+active+breathing+control+%28abc%29/pmc10511493__mmc2-15-27-31?v=CIVCO+Medical+Instruments+Co+Inc
Average 90 stars, based on 1 article reviews
sinmed posiboard-2 - by Bioz Stars, 2026-08
90/100 stars
  Buy from Supplier

90
Vision RT Ltd vrt-dibh (visionrt-based deep inspiration breath-hold
Vrt Dibh (Visionrt Based Deep Inspiration Breath Hold, supplied by Vision RT Ltd, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/deep+inspiration+breath-hold+with+active+breathing+control+%28abc%29/nct04686500-7-27-28?v=Vision+RT+Ltd
Average 90 stars, based on 1 article reviews
vrt-dibh (visionrt-based deep inspiration breath-hold - by Bioz Stars, 2026-08
90/100 stars
  Buy from Supplier

90
Siemens AG dibh-cts
Dibh Cts, supplied by Siemens AG, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/deep+inspiration+breath-hold+with+active+breathing+control+%28abc%29/10__2340_slash_1651___226x__2024__23964-68-9-16?v=Siemens+AG
Average 90 stars, based on 1 article reviews
dibh-cts - by Bioz Stars, 2026-08
90/100 stars
  Buy from Supplier

90
Siemens AG somatom definition scanner
Somatom Definition Scanner, supplied by Siemens AG, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/deep+inspiration+breath-hold+with+active+breathing+control+%28abc%29/pmc10483249-150-21-25?v=Siemens+AG
Average 90 stars, based on 1 article reviews
somatom definition scanner - by Bioz Stars, 2026-08
90/100 stars
  Buy from Supplier

90
Vision RT Ltd hard- and software tools
(A) Work flow of patient set-up and localization until treatment delivery together with (B) an example screenshot of one of our SBRT patients showing a typical region of interest (ROI) placed to the lower thorax for <t>DIBH</t> monitoring of a liver target.
Hard And Software Tools, supplied by Vision RT Ltd, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/deep+inspiration+breath-hold+with+active+breathing+control+%28abc%29/pmc07546313-58-4-12?v=Vision+RT+Ltd
Average 90 stars, based on 1 article reviews
hard- and software tools - by Bioz Stars, 2026-08
90/100 stars
  Buy from Supplier

90
TomoTherapy dibh treatments
(A) Work flow of patient set-up and localization until treatment delivery together with (B) an example screenshot of one of our SBRT patients showing a typical region of interest (ROI) placed to the lower thorax for <t>DIBH</t> monitoring of a liver target.
Dibh Treatments, supplied by TomoTherapy, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/deep+inspiration+breath-hold+with+active+breathing+control+%28abc%29/pm39138877-107-27-20?v=TomoTherapy
Average 90 stars, based on 1 article reviews
dibh treatments - by Bioz Stars, 2026-08
90/100 stars
  Buy from Supplier

90
TomoTherapy avmi/tomotherapy dibh
Guidelines, precautions, and advice for humanized monoclonal antibody (MAB) targeting HER2.
Avmi/Tomotherapy Dibh, supplied by TomoTherapy, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/deep+inspiration+breath-hold+with+active+breathing+control+%28abc%29/pmc10137001-10-61-61?v=TomoTherapy
Average 90 stars, based on 1 article reviews
avmi/tomotherapy dibh - by Bioz Stars, 2026-08
90/100 stars
  Buy from Supplier

90
Siemens AG computer tomography images (pct) in dibh
Guidelines, precautions, and advice for humanized monoclonal antibody (MAB) targeting HER2.
Computer Tomography Images (Pct) In Dibh, supplied by Siemens AG, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/deep+inspiration+breath-hold+with+active+breathing+control+%28abc%29/10__2340_slash_1651___226x__2024__23964-48-12-19?v=Siemens+AG
Average 90 stars, based on 1 article reviews
computer tomography images (pct) in dibh - by Bioz Stars, 2026-08
90/100 stars
  Buy from Supplier

90
NSABP Foundation nsabp-b51 protocol
Guidelines, precautions, and advice for humanized monoclonal antibody (MAB) targeting HER2.
Nsabp B51 Protocol, supplied by NSABP Foundation, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/deep+inspiration+breath-hold+with+active+breathing+control+%28abc%29/pmc06871569-180-2-9?v=NSABP+Foundation
Average 90 stars, based on 1 article reviews
nsabp-b51 protocol - by Bioz Stars, 2026-08
90/100 stars
  Buy from Supplier

Image Search Results


(A) Work flow of patient set-up and localization until treatment delivery together with (B) an example screenshot of one of our SBRT patients showing a typical region of interest (ROI) placed to the lower thorax for DIBH monitoring of a liver target.

Journal: Frontiers in Oncology

Article Title: Feasibility of Optical Surface-Guidance for Position Verification and Monitoring of Stereotactic Body Radiotherapy in Deep-Inspiration Breath-Hold

doi: 10.3389/fonc.2020.573279

Figure Lengend Snippet: (A) Work flow of patient set-up and localization until treatment delivery together with (B) an example screenshot of one of our SBRT patients showing a typical region of interest (ROI) placed to the lower thorax for DIBH monitoring of a liver target.

Article Snippet: For monitoring of correct DIBH reproducibility the hard- and software tools of Vision RT Ltd. (London, United Kingdom) were used.

Techniques:

Box plots with boxes extending from 25th to 75th percentiles. Whiskers are drawn down to 5th and up to 95th percentiles, respectively. (A) Couch shifts are shown in left (+) to right (–), cranial (+) to caudal (–) and anterior (+) to posterior (–) directions along the x -, y -, and z -axis, respectively. Values were grouped by target location and derived from first CBCTs for position verification after alignment of current DIBH surface to that of the reference surface. (B) Length of correction vectors of first CBCTs for image-guidance in DIBH and grouped by target location. Statistical difference was calculated by Welch’s t -test.

Journal: Frontiers in Oncology

Article Title: Feasibility of Optical Surface-Guidance for Position Verification and Monitoring of Stereotactic Body Radiotherapy in Deep-Inspiration Breath-Hold

doi: 10.3389/fonc.2020.573279

Figure Lengend Snippet: Box plots with boxes extending from 25th to 75th percentiles. Whiskers are drawn down to 5th and up to 95th percentiles, respectively. (A) Couch shifts are shown in left (+) to right (–), cranial (+) to caudal (–) and anterior (+) to posterior (–) directions along the x -, y -, and z -axis, respectively. Values were grouped by target location and derived from first CBCTs for position verification after alignment of current DIBH surface to that of the reference surface. (B) Length of correction vectors of first CBCTs for image-guidance in DIBH and grouped by target location. Statistical difference was calculated by Welch’s t -test.

Article Snippet: For monitoring of correct DIBH reproducibility the hard- and software tools of Vision RT Ltd. (London, United Kingdom) were used.

Techniques: Derivative Assay

Volumes of gross tumor (GTV), clinical target volume (CTV), internal target volume (ITV) and planning target in DIBH (CTV DIBH and PTV DIBH) as well as in free-breathing (ITV FB and PTV FB) for (A) all patients and (B) grouped by target location. Statistical differences were calculated by paired t -test.

Journal: Frontiers in Oncology

Article Title: Feasibility of Optical Surface-Guidance for Position Verification and Monitoring of Stereotactic Body Radiotherapy in Deep-Inspiration Breath-Hold

doi: 10.3389/fonc.2020.573279

Figure Lengend Snippet: Volumes of gross tumor (GTV), clinical target volume (CTV), internal target volume (ITV) and planning target in DIBH (CTV DIBH and PTV DIBH) as well as in free-breathing (ITV FB and PTV FB) for (A) all patients and (B) grouped by target location. Statistical differences were calculated by paired t -test.

Article Snippet: For monitoring of correct DIBH reproducibility the hard- and software tools of Vision RT Ltd. (London, United Kingdom) were used.

Techniques:

Guidelines, precautions, and advice for humanized monoclonal antibody (MAB) targeting HER2.

Journal: Cancers

Article Title: Interaction between Radiation Therapy and Targeted Therapies in HER2-Positive Breast Cancer: Literature Review, Levels of Evidence for Safety and Recommendations for Optimal Treatment Sequence

doi: 10.3390/cancers15082278

Figure Lengend Snippet: Guidelines, precautions, and advice for humanized monoclonal antibody (MAB) targeting HER2.

Article Snippet: Pertuzumab , 18 , Yes , ESMO: “It is recommended to decide on the administration of 1 year of trastuzumab/ Pertuzumab based on the risk assessment at diagnosis; the treatment may start before or after the surgery, in accordance with the approval wording by the regulators”. , Cautious in case of abdomen and pelvic irradiation that includes large GI volume , AVMI/tomotherapy DIBH [ ]. No data on fractionation. .

Techniques: Adjuvant, Irradiation, Biomarker Discovery